![]() The Manual is a companion to the DOE/PNNL 90.1 Section 11 and Appendix G Compliance Form and supports 20 editions of ANSI/ASHRAE Standard 90.1. Review Manual - The ASHRASE 90.1 Section 11 and Appendix G Submittal Review Manual (the Manual) is a comprehensive reference for reviewing modeling-based submittals. It standardizes compliance documentations and simplifies submittal reviews by code officials and administrators of above code program implementers.įor questions about use or customization of the form please contact the Building Energy Codes Help Desk It helps the modeler establish simulation inputs for the baseline/budget and proposed design models and includes a submittal checklist to ensure that all necessary supporting documentation is included in the submittal. This spreadsheet-based compliance form meets the documentation requirements of Standards 90.1-20 Section 11 Energy Cost Budget Method and Appendix G Performance Rating Method. Instead, the proposed building energy performance needs to exceed that of the baseline by an amount commensurate with the code year being evaluated.Ĭompliance Form - Proper enforcement of performance-based compliance submittals is necessary to ensure consistency and confidence in modeling results, yet, enforcement is a notoriously difficult process. Appendix G uses a stable baseline approach with efficiency levels set at values that are not intended to be updated with each new addition of the code.For example, in Appendix G credit is available for strategies not credited in ECB such as optimized window area and orientation, selection of more efficient HVAC and service water heating equipment type, right sizing HVAC equipment, efficient use of thermal mass, etc. Appendix G uses a more independent baseline where many of the characteristics of the baseline design are based on standard practice, meaning credit is available not only for exceeding prescriptive requirements in the code, but also for exceeding standard practice that is not regulated by the code.This approach is referred to as a dependent baseline. A building is deemed in compliance with ECB when the annual energy cost of the proposed design is no greater than the annual energy cost of the baseline building design.The baseline is essentially a clone of the proposed design with most of the building components adjusted to “just meet” current prescriptive requirements.The main differences between the ECB and PRM approaches in Standard 90.1 are the characteristics of the baseline building design. ![]() This is demonstrated using computer simulation to compare a proposed building design to a reference building design commonly referred to as a baseline. ![]() These methods provide more flexibility by allowing a designer to "trade off" compliance by not meeting some prescriptive requirements if the impact can be offset by exceeding other prescriptive requirements.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |